Wet Steam Calculator (Input T and x)
This calculator calculates the thermodynamic properties for wet steam (two phase) using the IAPWS-97
industrial formulation. It calculates saturation temperature, density, specific enthalpy, specific entropy and specific internal energy.
Input temperature shall be below T=373.946deg C and vapor quality between 0 and 1.
This site also contains a calculator for wet steam where the input is pressure and vapor
quality
Symbol | Property | Value | Unit |
---|---|---|---|
T | Temperature | 100.00 | ℃ |
x | Vapor quality | 1.0 | - |
p | Pressure | 1.014 | Bar(A) |
ρ | Density | 0.598 | kg/m3 |
h | Specific Enthalpy | 2675.572 | kJ/kg |
s | Specific Entropy | 7.3541 | kJ/(kg×K) |
u | Specific Internal Energy | 2506.0153 | kJ/kg |