Wet Steam Calculator (Input p and x)
This calculator calculates the thermodynamic properties for wet steam (two phase) using the IAPWS-97
industrial formulation. It calculates saturation temperature, density, specific enthalpy,
specific entropy and specific internal energy.
Input pressure shall be below 220.64 Bar(A) and vapor quality between 0 and 1.
This site also contains a calculator for wet steam where the input is temperature and vapor
quality
Symbol | Property | Value | Unit |
---|---|---|---|
T | Temperature | 99.97 | ℃ |
x | Vapor quality | 1.0 | - |
p | Pressure | 1.013 | Bar(A) |
ρ | Density | 0.598 | kg/m3 |
h | Specific Enthalpy | 2675.531 | kJ/kg |
s | Specific Entropy | 7.3544 | kJ/(kg×K) |
u | Specific Internal Energy | 2505.9848 | kJ/kg |